Product ID: PW-110A-06Y |
|
Switching Power Supply ( 116W, ATX Outputs, Open Frame ) ( PW-110A-06Y)
ATX type.
Total Power: 86 ~ 116 Watts.
Dimension: L 228 x W 55 x H 43 mm.
DC OUTPUT & FEATURES
| MODEL NO. | | DC OUTPUT (LOAD CURRENT) | | CONTINUOUS | +3.3V | +5V | -5V | +12V | -12V | +5Vsb | Remarks | | OUTPUT | MIN. | MAX. | MIN. | MAX. | MIN. | MAX. | MIN. | MAX. | MIN. | MAX. | MIN. | MAX. | | PW-110A-06Y | 116 WATTS | 0A | 3A | 1A | 10A | 0A | 0.1A | 0.3A | 3.5A | 0A | 0.5A | 0A | 1.5A | W/Fan (22.5CFM) | | 96 WATTS | 2A | 6A | 0.1A | 3.5A | 0.5A | 1.5A | W/O Fan | | | O/P Regulation | 5% | 5% | 5% | 8% | 10% | 5% | Ripple & Noise (Vp-p) | 50mV | 50mV | 50mV | 120mV | 120mV | 50mV |
|
Switching Power Supply
|
| |
Specifications:
- Input
- Input range: 115 / 230 VAC switch selectable.
- Frequency: 47 - 63Hz.
- Input current: 2.5A max. (RMS) 115VAC.
- Inrush current: < 80A peak @ 230VAC cold start @ 25 deg C.
- Efficiency: > 70% typical at full load.
- Output
- Hold up time: > 16ms at full load and 115VAC nominal line.
- Short circuit protection.
- Over load protection: Over load protected 145% max.
- Over voltage protection: 110% - 130% rated output on +5V only.
- Safety standards
- TUV EN 60950-1.
- UL 60950-1.
- CSA C22.2 No. 60950-1.
- EMC standards (meet)
- FCC Class B.
- CISPR22 Class B.
- EN 55022 Class B.
- CE.
- Environmental
- Operating temperature: 0 to +40 deg C ambient derate each output at 2.5% per degree from +40 to +70 deg C.
- Storage temperature: -10 to +70 deg C.
- Humidity: Non-condensing 20% to 90%.
- Temperature coefficient: +/-0.04% per degree C.
- MTBF: > 80,000 hours at full load and 25 deg C ambient temperature.
- Standard output wires
- PW-110A-06Y: 20P x / B4P + S4P x1.
|
|
|
|
|