Product ID: PW-M360B-1YXXX-X |
|
Medical Power Supply ( 360W, Single Output, U-channel and Enclosed type) ( PW-M360B-1YXXX-X)
* 5V / 1A Standby output
* 12V / 1A Output for FAN
* Remote inhibit function(Single wire)
* Power: 360 watts.
* With active PFC, PF > 0.9 @ 115VAC /230 VAC.
* Dimension: 203.2(L) X 118.5(W) X 38.5(H)mm (8" x 4.66" x 1.51")&
* Avaiable in U-Channel, End-Fan enclosed, and Top-Fan enclosed type
Download the PDF
| Model no. |
Output voltage |
Minimum load |
Maximum load with convection cooling |
Output watts |
O/P regulation |
Ripple & noise (Vp-p) |
| PW-M360B-1Y120-X (D) |
+12V |
0A |
30A |
360W |
5% |
120mV |
| PW-M360B-1Y240-X (D) |
+24V |
0A |
15A |
360W |
5% |
240mV |
| PW-M360B-1Y300-X (D) |
+30V |
0A |
12A |
360W |
5% |
300mV |
| PW-M360B-1Y360-X (D) |
+48V |
0A |
10A |
360W |
5% |
360mv |
| PW-M360B-1Y480-X (D) |
+24V |
0A |
7.5A |
360W |
5% |
480mV |
| PW-M360B-1Y540-X (D) |
+54V |
0A |
6.67A |
360W |
5% |
540mV |
| PW-M360B-1Y570-X (D) |
+57V |
0A |
6.32A |
360W |
5% |
570mV |
|
Medical Power Supply
|
| |
Specifications:
- Note:
- 1. Option: X=U, U-Channel, X=S, End Fan, X=T, Fan on top; D=Current share
- 2. Option U: max output 360W force air 30CFM cooling, Option S and T: max output 360W, +50°C ambient max.
- 3. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
- 4. Peak–to–peak with 20MHz bandwidth with a tantalum 10uF in parallel with a 0.1uF ceramic capacitor.
- Electrical specifications
- Input
- Input range : 90-264VAC
- Frequency : 47 - 63Hz
- Power factor : >0.9 @115VAC / 230VAC
- Inrush current : <17.5A peak @ 115VAC; <35A peak @ 230VAC cold start @25° deg C
- Input current : 4.5A max. @ 115VAC
- Efficiency : 83% @ 115VAC, 86% @ 230VAC typical at full load
- Leakage current : < 300uA @ 264VAC
- Isolation : Input to Output 5656 VDC, Input to Ground 2121 VDC, Output to Ground 707 VDC
- Output
- Maximum power : 360W force air 15CFM cooling
- Hold-up time :20ms @ 115VAC
- Short circuit protection : Auto recovery
- Over load protection : 110% to 150% maximum rating, Auto recovery
- Over voltage protection : 110% to 130% above nominal output, Latching type. AC Recycle
- Remote inhibit function
- Current share option ( Single wire )
- 5V / 1A Standby output
- 12V / 1A Output for FAN
- Environmental
- Operating temperature: 0°C to +50°C ambient derate each output at 2.5% per degree from +50°C to +70°C
- Humidity: Non-condensing 5% to 95%
- Temperature coefficient: ±0.04% per degree C
- MTBF demonstrated:>100,000 hours at full load and 25° deg C ambient temperature
- SAFETY STANDARDS
- UL UL60601-1
- CSA CSA-C22.2 NO.601.1-M90
- TUV EN60601-1
- CB IEC 60601-1
-
- EMI STANDARDS
- EN60601-1-2
- FCC Part 18 Class B
- EN55011 Class B
- CE
|
|
|
|
|