WORLDWIDE
Home / Product Line
170W AC-DC Desktop Adaptor AC Inlet-C14, A13170-XXZ
*ITE and Household Approvals
*3-pin IEC320-C14 or C6 Class I and 2-pin IEC320-C18 or C8 Class II models available
*Altitude during operation: 62368-1 :5000m, 61558-1 :2000m
*< 0.15W No Load Input Power
*Touch current less than 250uA
*Power ON LED indicator
*3 year warranty
*3-pin IEC320-C14 or C6 Class I and 2-pin IEC320-C18 or C8 Class II models available
*Altitude during operation: 62368-1 :5000m, 61558-1 :2000m
*< 0.15W No Load Input Power
*Touch current less than 250uA
*Power ON LED indicator
*3 year warranty
Description :
*Dimension : L 153×W 70×H 35 mm ( 6.03"x2.76"x1.38" )
*Weight : 0.57kgs. ( 1.26 lbs. )
Specification :
Electrical specifications
- Input range : 90 - 264VAC
- Frequency : 47 - 63Hz
- Power Factor : > 0.95 @115VAC; > 0.90 @230VAC @full load
- Inrush current : < 50A peak @115VAC; < 100A peak @230VAC cold start @25°C
- Input current (rms) : 2.2A @115VAC; 1A @230VAC max.
- Efficiency : > 89% @average Efficiency, 115/230VAC
92% @ 75% Full load, 230VAC (91% @ 12Vdc) - Maximum output power (Po) : 170Watts
- Hold–up time :> 20ms typical @ 80% Full load
- Short Circuit Protection: Auto-recovery
- Over Load Protection: Auto-recovery
- Over Voltage Protection: Latch off
- Over temperature protection: Auto-recovery
Safety standards
- UL 62368-1
- CSA C22.2-No.62368-1
- TUV EN62368-1
- CB IEC 62368-1
- CCC GB 4943. 1
- IEC/EN 61558-1( Class II)
- IEC/EN 61558-2-16(Class II)
EMC standards
- EN (BS EN) 55032 Class B
- EN (BS EN) 55035 Class B
- FCC Part 15 Class B
- CCC GB/T 9254. 1
- CCC GB17625. 1
- EN55014-1
- EN55014-2
- ICES-003
- CE.
Environmental
- Operating temperature: -20 to +60°C (Refer to derating curve)
- Operating Humidity: 10% to 95%, Non-condensing
- Storage temperature: -20°C to +85°C, Non-condensing
- Storage Humidity: 0% to 95%, Non-condensing
- MTBF : > 300,000 hours @full load and 25°C ambient temperature based on Telcordia SR-332( Bellcore)
Standard output cable
- 1. AWM 2464 #16AWG / 3C + SHIELDING, UL 80°C 300V VW-1, 1050 mm. (12-24V)
- 2. AWM 2464 #18AWG / 3C + SHIELDING, UL 80°C 300V VW-1, 1050 mm. (36-48V)
- 3. Depends on customers requirements.
DC OUTPUT & FEATURES
※
Other DC output 140W for 12-14V, 150W for 15-26V, 33-39V and 44-52V.
| Model | Output Rating | Po | O/P Regulation | Ripple & Noise (Vp-p) |
Peak Power (3s) |
Efficiency Level |
|
|---|---|---|---|---|---|---|---|
| A13170-12Z | +12V | 13.34A | 160W | ± 5% | 120mV | 200W | VII |
| A13170-19Z | +19V | 8.95A | 170W | ± 5% | 150mV | 200W | VII |
| A13170-24Z | +24V | 7.08A | 170W | ± 5% | 200mV | 200W | VII |
| A13170-36Z | +36V | 4.72A | 170W | ± 5% | 200mV | 200W | VII |
| A13170-48Z | +48V | 3.54A | 170W | ± 5% | 200mV | 200W | VII |
Note:
Note: 1. Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 47uF electrolytic capacitor and a
0.1uF ceramic capacitor in parallel at output connector.
2. AC Inlet Z=A : Class I, IEC320-C14, Z=B : Class I, IEC320-C6, Z=C : Class II, IEC320-C18, Z=D : Class II, IEC320-C8.
3. -1 to -20°C ambient temperature and EMS Immunity worst case O/P Regulation≦ +/-10%.
4. The switching frequency of this series is set within 60 to 90KHz at full load.
5. Peak power is usually applied at a typical nominal input voltage.
2. AC Inlet Z=A : Class I, IEC320-C14, Z=B : Class I, IEC320-C6, Z=C : Class II, IEC320-C18, Z=D : Class II, IEC320-C8.
3. -1 to -20°C ambient temperature and EMS Immunity worst case O/P Regulation≦ +/-10%.
4. The switching frequency of this series is set within 60 to 90KHz at full load.
5. Peak power is usually applied at a typical nominal input voltage.