POWER-WIN TECHNOLOGY CORP. designs best in class switching power supply and provides manufacturing services for switching power supply with high engineering content. Keeping in mind the importance of clients' time, we make sure that our products are delivered to them within the promises time-period. We ensure that our switching power supply goes through different quality tests to maintain the desired quality standards for our offerings. POWER-WIN TECHNOLOGY CORP. is known for our innovation and is persistently thriving to push development.

B24200-XX
200W AC-DC Open Frame , L101.6 × W50.8 ×H30 mm
*Both ITE & Household Approvals.
*High Power density, 200W in 4" x 2" footprint.
*Altitude during operation: ITE Below 5000m. & Household Below 2000m
*No load Power consumption < 150mW
*Suitable for both Class I and Class II application.
*Meet RoHS requirement
*3 year warranty
*High Power density, 200W in 4" x 2" footprint.
*Altitude during operation: ITE Below 5000m. & Household Below 2000m
*No load Power consumption < 150mW
*Suitable for both Class I and Class II application.
*Meet RoHS requirement
*3 year warranty
Description :
*Dimension : L101.6 × W50.8 ×H30 mm (4.00" x 2.00" x 1.18")
*Weight : 210g
Specification :
Electrical specifications
- Input range : 90 - 264VAC (Refer to derating curve)
- Frequency : 47 - 63Hz.
- Power Factor : > 0.95 @115VAC; > 0.90 @230VAC @full load.
- Inrush current :<40A peak @115VAC; <80A peak @230VAC cold start @25°C.
- Input current (rms) : 2.5A @115VAC; 1.2A @230VAC max.
- Efficiency : > 92% typical @ 75% load, 230VAC.
- Touch current < 250uA @264VAC.
- Maximum output power : 200Watts forced air, 120Watts convection cooling.
- Hold-up time : > 20ms typical @70% load, 115VAC.
- Short circuit protection : Auto-recovery.
- Over power protection : 105% to 150% maximum rating Auto-recovery.
- Over voltage protection : Latch off.
- Over temperature protection : Auto-recovery.
Safety standards
- UL/c-UL UL62368-1
- TUV EN62368-1
- CB IEC62368-1
- IEC/EN 61558-1
- IEC/EN 61558-2-16
- IEC/EN 60335-1
EMC standards
- EN55032 Class B
- EN55035
- FCC Part 15 Class B
- EN55014-1
- EN55014-2
- CE
Environmental
- Operating temperature : -20 to +70°C (Refer to derating curve).
- Storage temperature: -20°C to +85°C.
- Operating Humidity : 10-95% , non-condensing.
- Storage Humidity : 0-95%, non-condensing.
- MTBF : > 300,000 hours @full load and 25°C ambient temperature per Telcordia(Bellcore TR-332). .
DC OUTPUT & FEATURES
| Model no. | Output voltage | Maximum Load | Output Regulation | Ripple Noise | Convection total power |
18CFM Forced air total power |
EfficiencyLevel | |
|---|---|---|---|---|---|---|---|---|
| Convection | 18 CFM ForcedAir | |||||||
| B24200-12 | +12V | 10A | 16.67A | ±3% | 120mV | 120W | 200W | VI |
| B24200-19 | +19V | 6.32A | 10.53A | ±2% | 150mV | 120W | 200W | VI |
| B24200-24 | +24V | 5A | 8.34A | ±2% | 200mV | 120W | 200W | VI |
| B24200-36 | +36V | 3.34A | 5.56A | ±2% | 200mv | 120W | 200W | VI |
| B24200-48 | +48V | 2.5A | 4.17A | ±2% | 200mV | 120W | 200W | VI |
Note:
1. All models have total power 120W Max. convection or 200W Max. forced air cooling.
2. Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 100uF electrolytic capacitor and a
0.1uF ceramic capacitor in parallel at output connector.
3. The switching frequency of this series is set within 65 to 95KHz at full load.
POWER-WIN TECHNOLOGY CORP. has earned a reputation to support the switching power supply we sell with the best technical support and customer service in the electrical supplies industry. Our team of quality controllers tests each product before delivering to the client in order to ensure its flawlessness. Please visit any of our great locations to see the latest products from manufacturers like switching power supply and many more!