POWER-WIN TECHNOLOGY CORP.

Power-Win is a professional power supply manufacturer located in Taipei, Taiwan. Starting with PC power supplies business in 1989, Power-Win extends its product lines into AC / DC switching adapters, open frame power supplies, DC / DC ATX converters, and medical power supplies. With over 20 year experience in design, research, and manufacturing, Power-Win not only develops its own products to lead market trends and also works with customers for OEM / ODM projects. To meet latest energy saving demand and green power trend, we introduce more efficiency level V adapters and also open frame units to fulfill customer’s needs.

400W AD-DC Open Frame/U ChannelL 127 × W 81 × H 38.1 mm, PW-400B-1YXXXUM

POWER-WIN TECHNOLOGY CORP.'s mission, as a worldwide 400W AD-DC Open Frame/U Channel
L 127 × W 81 × H 38.1 mm
supplier, is to make its key technologies available to its final customers at an affordable price, by matching high quality. As an industry leader of 400W AD-DC Open Frame/U Channel
L 127 × W 81 × H 38.1 mm
, we can manufacture first-rate 400W AD-DC Open Frame/U Channel
L 127 × W 81 × H 38.1 mm, 360Watts Medical and ITE open frame power supply, 4x6
with reasonable price. Our prime focus is to deliver products that exceed the expectations of our clients in a cost-effective manner. If you need any help at choosing the right 400W AD-DC Open Frame/U Channel
L 127 × W 81 × H 38.1 mm to match your requirements, we are happy to quote tailored to your requirements.

PW-400B-1YXXXUM

400W AD-DC Open Frame/U Channel
L 127 × W 81 × H 38.1 mm

*Both ITE & Medical Approvals
*High Power density, 400W in 5" x 3.2" footprint.
*Medical applications Protection: Means of Patient Protection ( MOPP).
*Altitude during operation: ITE up to 5000m ,Medical Below 3000m.
*Meet Medical BF rated.
*Main output and Standby output Power ON LED indicators.
*3 years warranty
Description :

U-Type (U Channel)
*Dimension : L127 x W81 x H38.1mm
*Weight : 575g (1.27lbs.)

E-Type (U Channel with cover)
*Dimension : L127 x W81 x H42.1mm
*Weight : 617g(1.36lbs.)

T-Type (Top mounted fan)
*Dimension : L127 x W81 x H68mm
*Weight : 657g(1.45lbs.)

Specification :

ELECTRICAL SPECIFICATIONS
  • Input range : 90 - 264VAC (Refer to derating curve).
  • Frequency : 47 - 63Hz.
  • Power Factor : > 0.95 @115VAC; > 0.90 @230VAC @full load.
  • Inrush current : < 45A peak @115VAC; < 80A peak @230VAC cold start @25°C
  • Input current (rms) : 4.2A @115VAC; 2.1A @230VAC max.
  • Efficiency : > 91% typical @full load, 230VAC.
  • Earth leakage current < 100uA @264VAC.
  • Maximum output power : 400Watts forced air, 250Watts convection cooling.
  • Hold-up time : > 10ms typical 50% load, 115VAC
  • Short circuit protection : Auto-recovery.
  • Over power protection : 105% to 150% maximum rating, Auto-recovery.
  • Over voltage protection : Auto-recovery
  • 5Vsb meet ErP Lot 6 0.5W @ No load.
  • Remote control ( Inhibit ) function.
Environmental
  • Operating temperature : -20 to +70°C. (Refer to "Derating Curve")
  • Operating Humidity: Non-condensing 10% to 90%.
  • Storage temperature: -20°C to +85°C.
  • Storage Humidity: Non-condensing 0% to 90%.
  • MTBF : > 250,000 hours @full load and 25°C ambient temperature per telcordia(Bellcore TR-332).
Safety Standards
  • UL60601-1 3.1rd Edition
  • TUV EN60601-1 3.1rd Edition
  • CB IEC60601-1 3.1rd Edition
  • UL/c-UL UL62368-1
  • TUV EN62368-1
  • CB IEC62368-1
EMI Standards
  • IEC60601-1-2 Ed4:2014
  • EN60601-1-2 Ed4:2015
  • EN 55011 Class B
  • EN55032 Class B
  • EN55024 Class B
  • FCC Part 15 Class B
  • FCC Part 18 Class B
  • CE
Model no. Output Voltage (V1) Maximum Load (V1) Output Regulation (V1) Ripple Noise (V1)
Standby supply
(V2)
FAN output (V3) Convection total power Forced air
total power
25CFM
Convection Forced Air
25CFM
PW-400B-1Y120TM +12V 20.84A 33.33A ±3% 240mV 5V/0.3A 12V/0.25A 250W 400W
PW-400B-1Y240TM +24V 10.42A 16.66A ±3% 300mV 5V/0.3A 12V/0.25A 250W 400W
PW-400B-1Y280TM +28V 8.93A 14.28A ±3% 300mV 5V/0.3A 12V/0.25A 250W 400W
PW-400B-1Y480TM +48V 5.21A 8.33A ±3% 300mV 5V/0.3A 12V/0.25A 250W 400W
PW-400B-1Y540TM +54V 4.63A 7.40A ±3% 300mV 5V/0.3A 12V/0.25A 250W 400W
PW-400B-1Y120TM +12V 33.33A -- ±3% 240mV 5V/0.3A 12V/0.25A 400W --
PW-400B-1Y240TM +24V 16.66A -- ±3% 300mV 5V/0.3A 12V/0.25A 400W --
PW-400B-1Y280TM +28V 14.28A -- ±3% 300mV 5V/0.3A 12V/0.25A 400W --
PW-400B-1Y480TM +48V 8.33A -- ±3% 300mV 5V/0.3A 12V/0.25A 400W --
PW-400B-1Y540TM +54V 7.40A -- ±3% 300mV 5V/0.3A 12V/0.25A 400W --
Note:
  • Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 100uF electrolytic capacitor and a 0.1uF ceramic capacitor in parallel at output connector.
  • Regulation shows the percentage of absolute value of nominal output voltage.
  • Model option : C = E, E-Type (U Channel with cover)、C = U, U-Type (U Channel)
  • -1 to -20°C ambient temperature and EMS Immunity worse case O/P Regulation≦ +/-10%
  • Standby supply (V2) O/P Regulation +/-10%、Ripple and noise 150mV.
  • The switching frequency of this series is set within 58 to 75KHz at full load.


  • Safety and EMC Performance
    Description Safety EMC
    Medical equipment IEC 60601-1 :2005+A1 Third Edition (IEC 60601-1:2012 reprint )
    EN 60601-1 : 2006 + A11 + A1 + A12
    ANSI/AAMI ES60601-1 :2012 + A1 + A2
    CAN / CSA C22.2 No. 60601-1 :14 - Edition 3
    EC/EN 60601-1-2
    Ed4:2014 & EN55011 and FCC Part 18
    Audio/video, ITE equipment IEC 62368-1 :2014 ( Second Edition )
    EN 62368-1 : 2014 + A11
    UL 62368-1, 2nd Edition, 2014-12-01
    CAN / CSA C22.2 No. 62368-1 :14, 2nd Edition
    EN55032 & EN5502 & FCC part 15 (*) and ICES-003
    Tests for conformance to this requirement will be performed with final system (*) FCC PART15 compliance information and warnings:
    This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
  • This device may not cause harmful interference, and
  • this device must accept any interference received, including interference that may cause undesired operation


  • Insulation level and dielectric withstand (HI-POT)
    Audio/video, ITE equipment Isolation voltage Grade insulation
    Primary circuits to secondary circuits 4242Vdc Reinforced
    primany circuits to earth ground 2121Vdc Basic
    Secondary circuits to earth ground 2121Vdc Basic
    Note:
  • Production testing use dc voltage test 4 Sec.
  • Send Message
    Contact Information

    By submitting your contact information, you acknowledge that you consent to our processing data in accordance with the Privacy and Cookie Policy.

    POWER-WIN TECHNOLOGY CORP. is recognized by our customers as the best provider of 400W AD-DC Open Frame/U Channel
    L 127 × W 81 × H 38.1 mm
    throughout the world. Your complete satisfaction is our ultimate goal. We invite you to look at our Web site and you will find us to be a reliable source for your needs. We will establish long-term co-operation and growth together with your business. POWER-WIN TECHNOLOGY CORP. aims to design and build the world's best performing 400W AD-DC Open Frame/U Channel
    L 127 × W 81 × H 38.1 mm
    , creating the perfect products and services for every type of customer. For more details about our 400W AD-DC Open Frame/U Channel
    L 127 × W 81 × H 38.1 mm, 360Watts Medical and ITE open frame power supply, 4x6
    , please contact with us immediately.