Products

15/24W Medical Adapter
Medical Power Adapter ( 15 / 24W, A9 Class II series, Efficiency Level V Switching Adapter )

PW-M024A-1YXXXK0

24W AC-DC Desktop Adaptor
AC Inlet-C8

Features
*Medical 60601-1 3.2rd Edition approved
*2-pole IEC320-C8 AC inlet, Class II
*Medical safety approved ( 2 MOPP between primary to secondary )
*Meet US DoE & EU ErP efficiency level V requirements
*Altitude during operation up to 3000m
*Touch current less than 100uA
*No load Power consumption < 300mW
*Power ON LED indicator
*3 year warranty
View More Details
PDF Datasheet (622 KB)
Description
*Dimension : L78.8 × W51 × H35 mm ( 3.1" × 2" × 1.38")
*Weight : 0.13 kgs. ( 0.29 lbs. )
Specification
Electrical specifications
  • Input range : 90 - 264VAC
  • Frequency : 47 - 63Hz
  • Inrush current : < 30A peak @115VAC; < 60A peak @230VAC cold start @25°C
  • Input current (rms) : 0.7A @90VAC; 0.35A @264VAC max.
  • Efficiency : > 82.3% @Average efficiency, 115/230VAC
  • Maximum output power (Po) : 24Watts
  • Hold–up time : > 10ms typical @full load, 115VAC
  • Short Circuit Protection: Auto-recovery
  • Over Load Protection: Auto-recovery
  • Over Voltage Protection: latch off, AC recycle
Safety standards
  • UL/c-UL UL60601-1
  • TUV EN60601-1
  • CB IEC60601-1
EMC standards
  • EN(BS EN)60601-1-2
  • IEC60601-1-2
  • EN55011 Class B
  • FCC Part 18 Class B
  • CE
Environmental
  • Operating temperature : -20 to +60°C (Refer to derating curve).
  • Operating Humidity : 10% to +95% , non-condensing.
  • Storage temperature : -20°C to +85°C
  • Storage Humidity: 0% to +95% , non-condensing.
  • MTBF : >650,000 hours @full load and 25°C ambient temperature per Telcordia SR-332(Bellcore).
Standard output cable
  • 1. AWM 1185 # 18 AWG / 1C + SHIELDING, UL 80°C 300V VW-1, 1000 mm.(5V,9V)
  • 2. AWM 1185 # 18 AWG / 1C + SHIELDING, UL 80°C 300V VW-1, 1500 mm.(12V,16V,18V,24V,36V,48V)
  • 3. Depends on customers requirements.
  • Standard Output Cord: D0727 for 5V,9V
Model Output voltage Output current Po O/P Regulation Ripple & Noise
(Vp-p)
Energy
Level
PW-015A-1Y050K0 5V 3A 15W +5%/-3% 50mV V
PW-024A-1Y090K0 9V 2.67A 24W +5%/-3% 90mV V
PW-024A-1Y120K0 12V 2.00A 24W +5%/-3% 120mV V
PW-024A-1Y160K0 16V 1.50A 24W +5%/-3% 160mV V
PW-024A-1Y180K0 18V 1.34A 24W +5%/-3% 180mV V
PW-024A-1Y240K0 24V 1.00A 24W +5%/-3% 240mV V
PW-024A-1Y360K0 36V 0.67A 24W +5%/-3% 360mV V
PW-024A-1Y480K0 48V 0.50A 24W +5%/-3% 480mV V
Note:Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 10uF electrolytic capacitor and a 0.1uF ceramic capacitor in parallel at output connector.
Note:
Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 10uF electrolytic capacitor and a 0.1uF ceramic capacitor in parallel at output connector.

Loading...