DOE Level VI & EU ErP Tier 2 Efficiency Compliant,Medical AC/DC Power Adapter AD-A8 V2 Series 170/175Watts

DOE Level VI & EU ErP Tier 2 Efficiency Compliant

Medical AC/DC Power Adapter AD-A8 V2 Series 170/175Watts

Features
  • Medical 60601-1 3.1rd Edition approval
  • 3-pin IEC320-C14 or C6 Class I and 2-pin IEC320-C18 or C8 Class II models available
  • Medical safety approved ( 2x MOPP between primary to secondary ) Suitable for BF application with appropriate system consideration.
  • Altitude during operation: Medical up to 5000m.
  • ≦ 0.15W No Load Input Power
  • Touch current less than 100uA
  • Rectangular plastic case with IP41 level
  • 3 year warranty
View More Details
PDF Datasheet (681 KB)
Description
Electrical Specifications
  • Input range : 90 - 264VAC
  • Frequency : 47 - 63Hz
  • Power Factor : > 0.95 @115VAC; > 0.90 @230VAC @full load
  • Inrush current : < 50A peak @115VAC; < 100A peak @230VAC cold start @25°C
  • Input current (rms) : 2.5A @115VAC; 1.3A @230VAC max.
  • Efficiency : > 89% @average load, 115/230VAC
  • Touch current < 100uA @264Vac
  • Maximum output power (Po) : 170/175watts
  • Hold–up time : > 10ms typical @full load, 115VAC
  • Short Circuit Protection: Auto-recovery
  • Over Load Protection: Auto-recovery
  • Over Voltage Protection: Shutdown and latch off, AC recycle
Environmental
  • Operating temperature : -20 to +60°C (Derate linearly 2.5% per °C from 41 to 60°C)
  • Storage temperature : -20°C to +85°C
  • Humidity: 0% ~ 95%.
  • MTBF : > 400,000 hours at full load and 25°C ambient temperature based on Bellcore TR-332
RoHS Compliant
  • Dimension : L170 × W85 × H44 mm ( 6.69" × 3.35" × 1.73")
  • Weight : 0.79 kgs ( 1.73 lbs. )
Safety Standards
  • UL/cUL 60601-1 3.1rd Edition
  • TUV EN60601-1 3.1rd Edition
  • CB IEC60601-1 3.1rd Edition
Class II Versions Exclusive
  • EN60601-1-11 1st Edition
  • IEC60601-1-11 1st Edition
EMC Standards
  • EN60601-1-2 Ed4:2015
  • IEC60601-1-2 Ed4:2014
  • EN 55011 Class B
  • FCC Part 18 Class B
  • CE
DC Output & Functions
Model No. Output Rating Po O/P
Regulation
Ripple & Noise
(Vp-p)
DOE Efficiency EU ErP
PW-M170A2-1Y120HZ 12V 14.17A 170W ±5% 120mV VI Tier 2 
PW-M175A2-1Y150HZ 15V 11.67A 175W ±5% 150mV VI Tier 2 
PW-M175A2-1Y190HZ 19V 9.22A 175W ±5% 190mV VI Tier 2 
PW-M175A2-1Y240HZ 24V 7.30A 175W ±3% 240mV VI Tier 2 
PW-M175A2-1Y280HZ 28V 6.25A 175W ±3% 280mV VI Tier 2 
PW-M175A2-1Y360HZ 36V 4.87A 175W ±3% 360mV VI Tier 2 
PW-M175A2-1Y480HZ 48V 3.65A 175W ±3% 480mV VI Tier 2 
PW-M175A2-1Y540HZ 54V 3.25A 175W ±3% 540mV VI Tier 2 
Note:1. Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 10uF electrolytic capacitor and a 0.1uF ceramic capacitor in parallel at output connector. 2. AC Inlet Z=1 : Class I, IEC320-C14, Z=2 : Class I, IEC320-C6, Z=3 : Class II, IEC320-C18, Z=4 : Class II, IEC320-C8
Derating Curve
Standard Output Cable
1. AWM 2464 # 16 AWG / 3C + SHIELDING, UL 80°C 300V VW-1, 1050 mm. (12V, 15V & 19V)
2. AWM 2464 # 18 AWG / 3C + SHIELDING, UL 80°C 300V VW-1, 1050 mm. (24V, 28V, 36V, 48V & 54V)
3. Depends on customers requirements.