*ITE & Medical Approvals
*3-prong IEC320-C14, Class I AC inlet
*Medical safety approved ( 2x MOPP between primary to secondary )
Suitable for BF application with appropriate system consideration
*ITE/Medical up to 5000 meter altitude during operation
*< 0.5W No Load Input Power
*Touch current less than 100uA
*3 year warranty
Operating temperature : -20 to +60°C (Refer to Derating Curve)
Operating Humidity: 10% to 95%, Non-condensing.
Storage temperature: -20°C to +85°C, Non-condensing.
Storage Humidity: 0% to 95%, Non-condensing.
MTBF : > 230,000 hours @full load and 25°C ambient temperature based on Bellcore TR-332
DC OUTPUT & FEATURES
Model
Output Rating
Po
Output Regulation
Peak power (3s)
Ripple & Noise
(Vp-p)
Efficiency Level
115VAC
230VAC
A10400-12
+12V
31.66A
380W
±5%
480W
520W
120mV
VI
A10400-19
+19V
21.05A
400W
±5%
190mV
VI
A10400-24
+24V
16.66A
400W
±5%
240mV
VI
A10400-28
+28V
14.28A
400W
±5%
300mV
VI
A10400-48
+48V
8.33A
400W
±5%
300mV
VI
Note:
Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 47uF electrolytic capacitor and a 0.1uF ceramic capacitor in parallel at output connector.
(-1 to -20°C ambient temperature and EMS Immunity worse case O/P Regulation≦ +/-10%)
The switching frequency of this series is set within 56 to 85KHz at full load.
The ripple and noise of this series is tested under full load condition.