Products

400W / 500W Open Frame Power Supply

PW-400B-1YXXXUM

400W AD-DC Open Frame/U Channel
L 127 × W 81 × H 38.1 mm

Features
*Both ITE & Medical Approvals
*High Power density, 400W in 5" x 3.2" footprint.
*Medical applications Protection: Means of Patient Protection ( MOPP).
*Altitude during operation: ITE up to 5000m ,Medical Below 3000m.
*Meet Medical BF rated.
*Main output and Standby output Power ON LED indicators.
*3 years warranty
PDF Datasheet (2.1 MB)
Description
U-Type (U Channel)
*Dimension : L127 x W81 x H38.1mm
*Weight : 575g (1.27lbs.)

E-Type (U Channel with cover)
*Dimension : L127 x W81 x H42.1mm
*Weight : 617g(1.36lbs.)

T-Type (Top mounted fan)
*Dimension : L127 x W81 x H68mm
*Weight : 657g(1.45lbs.)
Specification
ELECTRICAL SPECIFICATIONS
  • Input range : 90 - 264VAC (Refer to derating curve).
  • Frequency : 47 - 63Hz.
  • Power Factor : > 0.95 @115VAC; > 0.90 @230VAC @full load.
  • Inrush current : < 45A peak @115VAC; < 80A peak @230VAC cold start @25°C
  • Input current (rms) : 4.2A @115VAC; 2.1A @230VAC max.
  • Efficiency : > 91% typical @full load, 230VAC.
  • Earth leakage current < 100uA @264VAC.
  • Maximum output power : 400Watts forced air, 250Watts convection cooling.
  • Hold-up time : > 10ms typical 50% load, 115VAC
  • Short circuit protection : Auto-recovery.
  • Over power protection : 105% to 150% maximum rating, Auto-recovery.
  • Over voltage protection : Auto-recovery
  • 5Vsb meet ErP Lot 6 0.5W @ No load.
  • Remote control ( Inhibit ) function.
Environmental
  • Operating temperature : -20 to +70°C. (Refer to "Derating Curve")
  • Operating Humidity: Non-condensing 10% to 90%.
  • Storage temperature: -20°C to +85°C.
  • Storage Humidity: Non-condensing 0% to 90%.
  • MTBF : > 250,000 hours @full load and 25°C ambient temperature per telcordia(Bellcore TR-332).
Safety Standards
  • UL60601-1 3.1rd Edition
  • TUV EN60601-1 3.1rd Edition
  • CB IEC60601-1 3.1rd Edition
  • UL/c-UL UL62368-1
  • TUV EN62368-1
  • CB IEC62368-1
EMI Standards
  • IEC60601-1-2 Ed4:2014
  • EN60601-1-2 Ed4:2015
  • EN 55011 Class B
  • EN55032 Class B
  • EN55024 Class B
  • FCC Part 15 Class B
  • FCC Part 18 Class B
  • CE
Model no. Output Voltage (V1) Maximum Load (V1) Output Regulation (V1) Ripple Noise (V1)
Standby supply
(V2)
FAN output (V3) Convection total power Forced air
total power
25CFM
Convection Forced Air
25CFM
PW-400B-1Y120TM +12V 20.84A 33.33A ±3% 240mV 5V/0.3A 12V/0.25A 250W 400W
PW-400B-1Y240TM +24V 10.42A 16.66A ±3% 300mV 5V/0.3A 12V/0.25A 250W 400W
PW-400B-1Y280TM +28V 8.93A 14.28A ±3% 300mV 5V/0.3A 12V/0.25A 250W 400W
PW-400B-1Y480TM +48V 5.21A 8.33A ±3% 300mV 5V/0.3A 12V/0.25A 250W 400W
PW-400B-1Y540TM +54V 4.63A 7.40A ±3% 300mV 5V/0.3A 12V/0.25A 250W 400W
PW-400B-1Y120TM +12V 33.33A -- ±3% 240mV 5V/0.3A 12V/0.25A 400W --
PW-400B-1Y240TM +24V 16.66A -- ±3% 300mV 5V/0.3A 12V/0.25A 400W --
PW-400B-1Y280TM +28V 14.28A -- ±3% 300mV 5V/0.3A 12V/0.25A 400W --
PW-400B-1Y480TM +48V 8.33A -- ±3% 300mV 5V/0.3A 12V/0.25A 400W --
PW-400B-1Y540TM +54V 7.40A -- ±3% 300mV 5V/0.3A 12V/0.25A 400W --
Note:
  • Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 100uF electrolytic capacitor and a 0.1uF ceramic capacitor in parallel at output connector.
  • Regulation shows the percentage of absolute value of nominal output voltage.
  • Model option : C = E, E-Type (U Channel with cover)、C = U, U-Type (U Channel)
  • -1 to -20°C ambient temperature and EMS Immunity worse case O/P Regulation≦ +/-10%
  • Standby supply (V2) O/P Regulation +/-10%、Ripple and noise 150mV.
  • The switching frequency of this series is set within 58 to 75KHz at full load.


  • Safety and EMC Performance
    Description Safety EMC
    Medical equipment IEC 60601-1 :2005+A1 Third Edition (IEC 60601-1:2012 reprint )
    EN 60601-1 : 2006 + A11 + A1 + A12
    ANSI/AAMI ES60601-1 :2012 + A1 + A2
    CAN / CSA C22.2 No. 60601-1 :14 - Edition 3
    EC/EN 60601-1-2
    Ed4:2014 & EN55011 and FCC Part 18
    Audio/video, ITE equipment IEC 62368-1 :2014 ( Second Edition )
    EN 62368-1 : 2014 + A11
    UL 62368-1, 2nd Edition, 2014-12-01
    CAN / CSA C22.2 No. 62368-1 :14, 2nd Edition
    EN55032 & EN5502 & FCC part 15 (*) and ICES-003
    Tests for conformance to this requirement will be performed with final system (*) FCC PART15 compliance information and warnings:
    This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
  • This device may not cause harmful interference, and
  • this device must accept any interference received, including interference that may cause undesired operation


  • Insulation level and dielectric withstand (HI-POT)
    Audio/video, ITE equipment Isolation voltage Grade insulation
    Primary circuits to secondary circuits 4242Vdc Reinforced
    primany circuits to earth ground 2121Vdc Basic
    Secondary circuits to earth ground 2121Vdc Basic
    Note:
  • Production testing use dc voltage test 4 Sec.
  • Loading...