500W AC-DC Open Frame/Enclosed L 143.0 x W 87.2 x H 46.5 mm
Features
*Both ITE & Medical Approvals.
*High Power density, 500W in 5" x 3" footprint.
*Medical safety approved ( 2 x MOPP between primary to secondary. )
*Altitude during operation: ITE up to 5000m ,Medical Below 3000m.
*Meet Medical BF rated.
*3 years warranty.
Input current (rms) : 6.3A @115VAC; 3A @230VAC max.
Efficiency : > 93% typical @70% full load, 230VAC.
Touch current < 100uA @264VAC.
Maximum output power : 500Watts forced air cooling.
Hold-up time : > 16ms typical @80% full load, 115VAC.
Short circuit protection : Auto-recovery.
Over load protection : Auto-recovery.
Over voltage protection : Latch off type. AC Recycle.
Over temperature protection : Latch off type. AC Recycle.
Safety standards
UL60601-1 3.1rd Edition
TUV EN60601-1 3.1rd Edition
CB IEC60601-1 3.1rd Edition
UL/c-UL UL62368-1
TUV EN62368-1
CB IEC62368-1
EMC standards
EN60601-1-2
EN55011 Class B
EN55032 Class B
EN55035
FCC Part 15 Class B
FCC Part 18 Class B
CE
Environmental
Operating temperature : -20 to +70°C (Refer to derating curve).
Operating Humidity: 10% to 95%, non-condensing.
Storage temperature: -20°C to +85°C.
Storage Humidity: 0% to 95%, non-condensing.
MTBF : > 240,000 hours@full load and 25°C ambient temperature per Telcordia(Bellcore).
Standard output cable
AWM 1185 # 18 AWG / 1C + SHIELDING, UL 80°C 300V VW-1, 1550 mm.
Depends on customers requirements.
Model No.
Main Output (V1)
Output (V2)
Convection total power
(100-120Vac )
Convection total power
(200-264Vac)
25CFM
Forced air
total power
Output Voltage
Convection
(100-120Vac)
Convection
(200-264Vac)
Forced air
12VFAN
B-Type
PW-500B2-1Y120BZ
+12V
18.33A
23.33A
41.6A
12V/0.3A
220W
280W
500W
PW-500B2-1Y240BZ
+24V
9.16A
11.66A
20.8A
PW-500B2-1Y480BZ
+48V
4.58A
5.83A
10.4A
E-Type
PW-500B2-1Y120EZ
+12V
17.5A
23.33A
41.6A
12V/0.3A
210W
280W
500W
PW-500B2-1Y240EZ
+24V
8.75A
11.66A
20.8A
PW-500B2-1Y480EZ
+48V
4.37A
5.83A
10.4A
Note:
Output connector options: Z=T ( Terminal block type ) , Z=M (Mini Fit type ) or Z=C ( Connector type )
Output voltage regulation 12V ± 3% , 24V and 48V ± 2% , With ripple and noise ≤1% for all models. ( -1~-20℃ ambient temperature and EMS immunity output voltage regulation worst case ≦ 5% )
Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 100uF electrolytic capacitor and a 0.1uF ceramic capacitor in parallel at output wire 300mm length connector.
Convection total Power, B-Type 220W or E-Type 210W (input 100-120Vac) or 280W (Input 200-264Vac) and 500W forced air cooling.
Output derating refer operating derating curve.
The switching frequency of this series is set 60~90KHz at full load.