WORLDWIDE

Products

150W~180W Medical Power Supply Open Frame

PW-150B-1YXXXUMZX

150W AC-DC Open Frame/U Channel
L 90.6 × W 64.0 × H 38.0 mm

Features
*Both ITE & Medical Approvals.
*High Power density, 150W in 3" x 2" footprint.
*Medical applications Protection: Means of Patient Protection ( MOPP).
*Altitude during operation: ITE & Medical Below 5000m.
*Meet Medical BF rated.
*Main output Power ON LED indicators.
*No load Power consumption < 150mW
*3 year warranty
View More Details
PDF Datasheet (1.1 MB)
Description
Open Frame type
*Dimension : L76.2 × W50.8 × H30.0 mm ( 3" x 2" x 1.18" )
*Weight : 0.15 kgs. (0.34 lbs. )

U-channel type
*Dimension : L90.6 × W64.0 × H38.0 mm (3.57" x 2.52" x 1.50")
*Weight : 0.20 kgs. (0.44 lbs. )

Enclosed type
*Dimension : L90.6 × W64.0 × H39.2 mm (3.57" x 2.52" x 1.55")
*Weight : 0.21 kgs. (0.47 lbs. )
Specification
Electrical specifications
  • Input range : 90 - 264VAC
  • Frequency : 47 - 63Hz
  • Power Factor : > 0.9 @115/230VAC @full load
  • Inrush current : < 45A peak @115VAC; < 90A peak @230VAC cold start @25°C
  • Input current (rms) : 2.5A @115VAC; 1.25A @230VAC max.
  • Efficiency : > 87% @average load, 115/230Vac
  • Maximum output power (Po) : 150 Watts forced air, 100 Watts convection cooling
  • Hold-up time : > 10ms typical @full load, 115VAC
  • Short circuit protection : Auto-recovery
  • Over load protection : 105% to 160% maximum rating, Auto-recovery
  • Over voltage protection : Shutdown
Safety standards
  • UL60601-1 3.1rd Edition
  • TUV EN60601-1 3.1rd Edition
  • CB IEC60601-1 3.1rd Edition
  • UL/c-UL UL62368-1
  • TUV EN62368-1
  • CB IEC62368-1
EMC standards
  • EN60601-1-2
  • EN55011 Class B
  • EN55032 Class B
  • EN55024
  • FCC Part 15 Class B
  • FCC Part 18 Class B
  • CE
Environmental
  • Operating temperature : -20 to +70°C (Refer to derating curve).
  • Storage temperature: -20°C to +85°C.
  • Humidity: Non-condensing 10% to 95%.
  • MTBF : > 400,000 hours @full load and 25°C ambient temperature per Telcordia(Bellcore TR-332).
DC OUTPUT & FEATURES
Model no. Output voltage Maximum Load OutputRegulation RippleNoise Convectiontotal power 10CFMForced airtotal power EfficiencyLevel
Convection 10 CFM ForcedAir
PW-150B-1Y120CSBX +12V 8.34A 12.50A ±3% 120mV 100W 150W VI
PW-150B-1Y150CSBX +15V 6.67A 10.00A ±3% 150mV 100W 150W VI
PW-150B-1Y180CSBX +18V 5.56A 8.34A ±3% 180mV 100W 150W VI
PW-150B-1Y240CSBX +24V 4.17A 6.25A ±3% 240mv 100W 150W VI
PW-150B-1Y280CSBX +28V 3.58A 5.36A ±3% 280mV 100W 150W VI
PW-150B-1Y360CSBX +36V 2.78A 4.17A ±2% 360mV 100W 150W VI
PW-150B-1Y480CSBX +48V 2.09A 3.13A ±2% 360mV 100W 150W VI
PW-150B-1Y540CSBX +54V 1.86A 2.78A ±2% 360mV 100W 150W VI
Note:
  • All models have total power 100W Max. convection or 150W Max. forced air cooling.
  • Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 10uF electrolytic capacitor and a 0.1uF ceramic capacitor in parallel at output connector.
  • Model option : C = B,open frame type C = U,U-channel C = E,Enclosed
  • Safety option: S = M (Medical & ITE) S = I (ITE only)
  • Output connector option: B=J (JST VH type) B = T (Eurostyle P.C.B. Terminal Block)
  • Medical Class I & Class II option code: X = Blank (Class I) X = 2 (Class II)
  • Loading...