600W Medical Power Supply Open Frame

B46600-XXE-M

600W AC-DC Open Frame/Enclosed
( L 152.4 × W 101.6 × H 43.5 mm )

Features
*Both ITE & Medical Approvals.
*High Power density, 600W in 6" x 4" footprint.
*Medical applications Protection: Means of Patient Protection ( MOPP).
*Altitude during operation: ITE Below 5000m. & Medical Below 3000m.
*Meet Medical BF rated.
*No load Power consumption < 500mW (for 5Vsb standby mode)
*Meet RoHS requirement
*3 year warranty
View More Details
PDF Datasheet (652 KB)
Description
*Dimension : L152.4 × W101.6 × H42.0 mm (6.00" x 4.00" x 1.66")
*U-Channel type Weight : 0.68 kgs. (1.50 lbs. )
*Dimension : L152.4 × W101.6 × H43.5 mm (6.00" x 4.00" x 1.72")
*Enclosed type Weight : 0.70 kgs. (1.55 lbs. )
Specification
Electrical specifications
  • Input range : 90 - 264VAC
  • Frequency : 47 - 63Hz
  • Power Factor : > 0.95 @115VAC; > 0.90 @230VAC @full load
  • Inrush current :<40A peak @115VAC; <80A peak @230VAC cold start @25°C.
  • Input current (rms) : 8A @115VAC; 4A @230VAC max.
  • Efficiency : > 93% typical @half load, 230VAC
  • Touch current < 100uA @264VAC.
  • Maximum output power : 600Watts forced air, 300/340Watts convection cooling.
  • Hold-up time : > 10ms typical @full load, 115VAC.
  • Short circuit protection : Auto-recovery.
  • Over power protection : 105% to 130% maximum rating, Auto-recovery.
  • Over voltage protection : Latching type. AC Recycle or SD pin is reset.
  • Over temperature protection : Latching type. AC Recycle or SD pin is reset.
  • Standby and FAN output supply
  • Remote control (Inhibit) function
Safety standards
  • UL60601-1
  • TUV EN60601-1
  • CB IEC60601-1
  • UL/c-UL UL62368-1
  • TUV EN62368-1
  • CB IEC62368-1
EMC standards
  • EN60601-1-2
  • EN55011 Class B
  • EN55032 Class B
  • EN55035
  • FCC Part 15 Class B
  • FCC Part 18 Class B
  • CE
Environmental
  • Operating temperature : -20 to +70°C (Refer to derating curve).
  • Storage temperature: -20°C to +85°C.
  • Operating Humidity : 10-95% , non-condensing. Storage Humidity : 0-95%, non-condensing.
  • MTBF : > 200,000 hours @full load and 25°C ambient temperature per Telcordia(Bellcore TR-332).
DC OUTPUT & FEATURES
Model Output Voltage Maximum Load Output
Regulation
Ripple
Noise
Standby
supply (V2)
FAN
supplu (V3)
Convection totalpower
(115/230Vac)
30CFM Forced airtotal power
Convection
(115/230Vac)
30 CFM
Forced Air
B46600-12C-S +12V 25.00A/28.33A 50.00A ±3% 120mV 1.0A 0.3A 300W/340W 600W
B46600-24C-S +24V 12.50A/14.17A 25.00A ±3% 240mV 1.0A 0.3A 300W/340W 600W
B46600-28C-S +28V 10.72A/12.14A 21.43A ±3% 280mV> 1.0A 0.3A 300W/340W 600W
B46600-36C-S +36V 8.34A/9.44A 16.67A ±2% 300mV 1.0A 0.3A 300W/340W 600W
B46600-48C-S +48V 6.25A/7.08A 12.50A ±2% 300mV 1.0A 0.3A 300W/340W 600W
Note:
  • All models have total power 300W/340W Max. convection or 600W Max. forced air cooling.
  • Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 47uF electrolytic capacitor and a
    0.1uF ceramic capacitor in parallel at output connector.
  • Model option : C = U,U-channel C = E,Enclosed
  • Safety option : S = M (Medical & ITE) S = I (ITE only)
  • The switching frequency of this series is set within 65 to 75KHz at full load.
  • Loading...