Products

360W Medical Power Supply Open Frame

PW-IM360B-1YXXXZ,360Watts Medical and ITE open frame power supply, 4x6, 2xMOPP, BF rated, Single Output

360Watts Medical and ITE open frame power supply, 4x6, 2xMOPP, BF rated, Single Output

PW-IM360B-1YXXXZ

Features

*Both ITE & Medical Approvals.
*High Power density, 360W in 6" x 4" footprint.
*Medical applications Protection: Means of Patient Protection ( MOPP).
*Altitude during operation: ITE up to 5000m ,Medical Below 3000m.
*Meet Medical BF rated.
*Main output and Standby output Power ON LED indicators.
*3 years warranty.
View More Details
PDF Datasheet (364 KB)
Specification
ELECTRICAL SPECIFICATIONS
  • Input range : 90 - 264VAC (Refer to derating curve).
  • Frequency : 47 - 63Hz.
  • Power Factor : > 0.95 @115VAC; > 0.90 @230VAC @full load.
  • Inrush current :<40A peak @115VAC; <80A peak @230VAC cold start @25°C.
  • Input current (rms) : 5A @115VAC; 2.5A @230VAC max.
  • Efficiency : > 90% typical @full load, 230VAC.
  • Earth leakage current < 100uA @264VAC.
  • Maximum power : 360 Watts with 15CFM forced air cooling (U-channel type)
  • Maximum output power : 360Watts forced air, 250Watts convection cooling.
  • SHold-up time : > 10ms typical @full load, 115VAC.
  • Short circuit protection : Auto-recovery.
  • Over power protection : 105% to 150% maximum rating, Auto-recovery.
  • Over voltage protection : Latching type. AC Recycle.
  • 5Vsb meet ErP 0.5W @ No load.
  • Remote control ( Inhibit ) function.
Environmental
  • Operating temperature : 0 to +70°C (Refer to derating curve).
  • Storage temperature: -20°C to +85°C.
  • Humidity: Non-condensing 0% to 90%.
  • MTBF : > 250,000 hours @full load and 25°C ambient temperature per Telcordia(Bellcore TR-332).
Safety Standards
  • UL60601-1 3rd Edition
  • UL/c-UL UL60950-1
  • EN60601-1 3rd Edition
  • TUV EN60950-1
  • IEC EN60601-1 3rd Edition
  • CB IEC 60950-1
EMI Standards
  • EN60601-1-2
  • EN55024
  • EN 55011 Class B
  • EN55032 Class B
  • FCC Part 15 Class B
  • FCC Part 18 Class B
  • CE
RoHS compliant
  • Dimension : L152.4 × W101.6 × H30.0 mm ( 6" x 4" x 1.18" )
  • Weight : 0.48 kgs. (1.06 lbs. )
Model no. Output Voltage (V1) Maximum Load (V1) Output Regulation (V1) Ripple Noise (V1)
Standby supply (V2) FAN output (V3) Convection total power 20CFM Forced air total power
Convection 18 CFM Forced Air
PW-IM360B-1Y120Z +12V 20.84A 30.00A ±3% 120mV 5V/0.5A 12V/0.3A 250W 360W
PW-IM360B-1Y240Z +24V 10.42A 15.00A ±3% 240mV 5V/0.5A 12V/0.3A 250W 360W
PW-IM360B-1Y280Z +28V 8.93A 12.86A ±2% 280mV 5V/0.5A 12V/0.3A 250W 360W
PW-IM360B-1Y480Z +48V 5.21A 7.50A ±2% 300mV 5V/0.5A 12V/0.3A 250W 360W
PW-IM360B-1Y540Z +54V 4.63A 6.67A ±2% 300mV 5V/0.5A 12V/0.3A 250W 360W

Note:
1. Output connector options: Z=T ( Terminal block type, pitch 8.25mm): Suitable for all voltages PW-IM360B-1Y240Z PW-IM360B-1Y280Z PW-IM360B-1Y480Z PW-IM360B-1Y540Z Z=C ( Connector type, pitch=3.96mm ): Suitable for 24V up
2. All models are equiped with 5Vsb & 12V fan outputs.
3. All models have total power 250W Max. convection or 360W Max. forced air cooling.
4. Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 10uF electrolytic capacitor and a 0.1uF ceramic capacitor in parallel at output connector. POWER WIN TECHNOLOGY CORP