WORLDWIDE

Products

400W Medical Adapter
  • Facebook
  • LINE
  • X
  • LinkedIn

A10400-XXM

400W AC-DC Desktop Adaptor
AC Inlet-C14

Features
*ITE & Medical Approvals
*3-prong IEC320-C14, Class I AC inlet
*Medical safety approved ( 2x MOPP between primary to secondary )
Suitable for BF application with appropriate system consideration
*ITE/Medical up to 5000 meter altitude during operation
*< 0.5W No Load Input Power
*Approval IP42
*Touch current less than 100uA
*3 year warranty
View More Details
PDF Datasheet (462 KB)
Description
*Dimension : L 222×W 112×H45 mm ( 8.74"x4.4"x1.77" )
*Weight : 1.63 kgs. ( 3.59 lbs. )
Specification
Electrical specifications
  • Input range : 90 - 264VAC
  • Frequency : 47 - 63Hz
  • Power Factor : > 0.95 @115VAC; > 0.90 @230VAC @full load
  • Input current (rms) : 4.2A @115VAC; 2.1A @230VAC max.
  • Efficiency : > 92% @80% Full load, 230VAC
  • Efficiency : > 87.5% @Average efficiency, 115/230VAC
  • Touch current: < 100uA @264VAC
  • Hold-up time : > 10ms typical @full load, 115VAC
  • Short circuit protection : Auto-recovery
  • Over load protection : Auto-recovery
  • Over voltage protection : Auto-recovery
  • Over temperature protection : Auto-recovery
  • Maximum output power (Po) : 380/400 Watts convection cooling
  • Inrush current; cold start @25C: < 35A peak @115VAC
    < 70A peak @230VAC
Safety standards
  • UL/cUL 60601-1
  • TUV EN60601-1
  • CB IEC60601-1
  • UL/c-UL UL62368-1
  • TUV EN62368-1
  • CB IEC62368-1
EMC standards
  • EN60601-1-2
  • EN 55011 Class B
  • EN55032 Class B
  • EN55035 Class B
  • FCC Part 15 Class B
  • FCC Part 18 Class B
  • CE
Environmental
  • Operating temperature : -20 to +60°C (Refer to Derating Curve)
  • Operating Humidity: 10% to 95%, Non-condensing.
  • Storage temperature: -20°C to +85°C, Non-condensing.
  • Storage Humidity: 0% to 95%, Non-condensing.
  • MTBF : > 230,000 hours @full load and 25°C ambient temperature based on Bellcore TR-332
DC OUTPUT & FEATURES
Model Output Rating Po Output Regulation Peak power (3s) Ripple & Noise
(Vp-p)
Efficiency Level
115VAC 230VAC
A10400-12 +12V 31.66A 380W ±5% 480W 520W 120mV VI
A10400-19 +19V 21.05A 400W ±5% 190mV VI
A10400-24 +24V 16.66A 400W ±5% 240mV VI
A10400-28 +28V 14.28A 400W ±5% 300mV VI
A10400-48 +48V 8.33A 400W ±5% 300mV VI
Note:
  • Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 47uF electrolytic capacitor and a 0.1uF ceramic capacitor in parallel at output connector.
  • (-1 to -20°C ambient temperature and EMS Immunity worse case O/P Regulation≦ +/-10%)
  • The switching frequency of this series is set within 56 to 85KHz at full load.
  • The ripple and noise of this series is tested under full load condition.
  • Loading...