PW-500B2-1YXXX-BZ
500W AC-DC Open Frame
L 127.0 x W 76.2 x H 34 mm
*Both ITE & Medical Approvals.
*High Power density, 500W in 5" x 3" footprint.
*Medical safety approved ( 2 x MOPP between primary to secondary. )
*Altitude during operation: ITE up to 5000m ,Medical Below 3000m.
*Meet Medical BF rated.
*3 years warranty.
*High Power density, 500W in 5" x 3" footprint.
*Medical safety approved ( 2 x MOPP between primary to secondary. )
*Altitude during operation: ITE up to 5000m ,Medical Below 3000m.
*Meet Medical BF rated.
*3 years warranty.
Description
B-Type
*Open frame
*L127xW76.2xH34mm
*Weight: 420g
E-Type
*U Channel with cover
*L143xW87.2xH46.5mm
*Weight: 550g
*Open frame
*L127xW76.2xH34mm
*Weight: 420g
E-Type
*U Channel with cover
*L143xW87.2xH46.5mm
*Weight: 550g
Specification
Electrical specifications
- Input range : 90 - 264VAC (Refer to derating curve).
- Frequency : 47 - 63Hz.
- Power Factor : > 0.95 @115VAC; > 0.90 @230VAC @full load.
- Inrush current :<40A peak @115VAC; <80A peak @230VAC cold start @25°C.
- Input current (rms) : 6.3A @115VAC; 3A @230VAC max.
- Efficiency : > 93% typical @70% full load, 230VAC.
- Touch current < 100uA @264VAC.
- Maximum output power : 500Watts forced air cooling.
- Hold-up time : > 16ms typical @80% full load, 115VAC.
- Short circuit protection : Auto-recovery.
- Over load protection : Auto-recovery.
- Over voltage protection : Latch off type. AC Recycle.
- Over temperature protection : Latch off type. AC Recycle.
Safety standards
- UL60601-1 3.1rd Edition
- TUV EN60601-1 3.1rd Edition
- CB IEC60601-1 3.1rd Edition
- UL/c-UL UL62368-1
- TUV EN62368-1
- CB IEC62368-1
EMC standards
- EN60601-1-2
- EN55011 Class B
- EN55032 Class B
- EN55035
- FCC Part 15 Class B
- FCC Part 18 Class B
- CE
Environmental
- Operating temperature : -20 to +70°C (Refer to derating curve).
- Operating Humidity: 10% to 95%, non-condensing.
- Storage temperature: -20°C to +85°C.
- Storage Humidity: 0% to 95%, non-condensing.
- MTBF : > 240,000 hours@full load and 25°C ambient temperature per Telcordia(Bellcore).
Standard output cable
- AWM 1185 # 18 AWG / 1C + SHIELDING, UL 80°C 300V VW-1, 1550 mm.
- Depends on customers requirements.
| Model No. | Main Output (V1) | Output (V2) | Convection total power (100-120Vac ) |
Convection total power (200-264Vac) |
25CFM Forced air total power |
||||
|---|---|---|---|---|---|---|---|---|---|
| Output Voltage | Convection (100-120Vac) |
Convection (200-264Vac) |
Forced air | 12VFAN | |||||
| B-Type | PW-500B2-1Y120BZ | +12V | 18.33A | 23.33A | 41.6A | 12V/0.3A | 220W | 280W | 500W |
| PW-500B2-1Y240BZ | +24V | 9.16A | 11.66A | 20.8A | |||||
| PW-500B2-1Y480BZ | +48V | 4.58A | 5.83A | 10.4A | |||||
| E-Type | PW-500B2-1Y120EZ | +12V | 17.5A | 23.33A | 41.6A | 12V/0.3A | 210W | 280W | 500W |
| PW-500B2-1Y240EZ | +24V | 8.75A | 11.66A | 20.8A | |||||
| PW-500B2-1Y480EZ | +48V | 4.37A | 5.83A | 10.4A | |||||
Note:
- Output connector options: Z=T ( Terminal block type ) , Z=M (Mini Fit type ) or Z=C ( Connector type )
- Output voltage regulation 12V ± 3% , 24V and 48V ± 2% , With ripple and noise ≤1% for all models. ( -1~-20℃ ambient temperature and EMS immunity output voltage regulation worst case ≦ 5% )
- Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 100uF electrolytic capacitor and a 0.1uF ceramic capacitor in parallel at output wire 300mm length connector.
- Convection total Power, B-Type 220W or E-Type 210W (input 100-120Vac) or 280W (Input 200-264Vac) and 500W forced air cooling.
- Output derating refer operating derating curve.
- The switching frequency of this series is set 60~90KHz at full load.