WORLDWIDE

Products

61W-80W Desktop Power Supply
65W AC-DC Desktop Adaptor

A14065-XX

65W AC-DC Desktop Adaptor
AC Inlet C14

Features
*3-prong IEC 320-C14, Class I AC inlet
*Meet US DOE level VI & EU ErP requirements.
*No load Power consumption <75mW
*Power on LED indicator
*3 year warranty
View More Details
PDF Datasheet (495 KB)
Description
*Dimension : L130 ×W47.5 ×H32 mm ( 5.12"× 1.87"× 1.26")
*Weight : 0.275 kgs. ( 0.606 lbs. )
Specification
Electrical specifications
  • Input range : 90 - 264VAC
  • Frequency : 47 - 63Hz
  • Inrush current : < 45A peak @115VAC; < 90A peak @230VAC cold start @25°C
  • Input current (rms) : 2A @90VAC; 1A @264VAC max.
  • Efficiency : > 89% @average Load, 115/230VAC
  • Maximum output power (Po) : 65Watts
  • Hold–up time : > 10ms typical @full load, 115VAC
  • Short Circuit Protection: Auto-recovery
  • Over Load Protection: Auto-recovery
  • Over Voltage Protection: Latch off
Safety standards
  • UL 62368-1
  • CSA C22.2-No.62368-1
  • TUV EN62368-1
  • CB IEC 62368-1
EMC standards
  • EN (BS EN) 55032 Class B
  • EN (BS EN) EN55035
  • FCC Part15 Class B
  • ICES-003
  • CE
Environmental
  • Operating temperature : -20 to +60°C (Refer to Derating Curve next page)
  • Operating Humidity: 10-95% , non-condensing.
  • Storage temperature : -20°C to +85°C
  • Storage humidity : 0-95% , non-condensing.
  • MTBF : > 200,000 hours at full load and 25°C ambient temperature based on Bellcore TR-332
Model Output voltage Output current Po O/P Regulation Ripple & Noise
(Vp-p)
Efficiency
Level
LPS
A14065-05 5V 8A 40W ±5% 120mV VI
A14065-12 12V 5A 60W ±5% 120mV VI
A14065-15 15V 4A 60W ±5% 120mV VI
A14065-19 19V 3.42A 65W ±3% 120mV VI
A14065-24 24V 2.71A 65W ±3% 120mV VI
A14065-28 28V 2.32A 65W ±3% 120mV VI
A14065-48 48V 1.35A 65W ±3% 120mV VI
Note:
  • Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 100uF electrolytic capacitor and a
    0.1uF ceramic capacitor in parallel at output connector.
  • -1 to -20°C ambient temperature and EMS Immunity worse case O/P Regulation ≦ ±10%.
  • The switching frequency of this series is set within 60 to 90KHz at full load.
  • Safety and EMC Performance
    Description Safety EMC
    Audio / Video, ITEequipment IEC 62368-1 : 2018
    EN IEC 62368-1:2020+A11:2020
    UL 62368-1, 3rd Edition
    CAN/CSA C22.2 No. 62368-1:19, 3rd Edition
    EN 55032:2015+A11:2020
    EN 55035:2017+A11:2020
    FCC 47 CFR Part 15B
    ICES-003 Issue 7
    Tests for conformance to this equirement will be performed with final system (*) FCC PART 15 compliance information and warings:
    This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions :
  • This device may not cause harmful interference.
  • This device must accept any interference received, including interference that may cause undesired operation.

  • Insulation level and dielectric withstand (HI-POT)
    Audio / video, ITE equipment Isolation voltage Grade insulation
    Primary to Secondary 4242Vdc (3000Vac) Reinforced
    Primary to Ground (Mounting holes or Frame GND) 2121Vdc (1500Vac) Basic
    Secondary circuits to earth ground 500Vdc Basic
    Note : Production testing use dc voltage test 4 Sec.